STEEL ROOFING
Surface temperature must be at least 10º C ( 50º F) before applying acrylic steel roofing.  Tighten all screws or replace them with the next largest size if they are spinning. Remove loose rust, dirt, oily residues with high pressure wash. Rusted steel roofing must be primed with a good quality rust primer such as our Rustite Direct to Metal Rust Primer. Problem seams and holes can be filled with our Lap Joint Sealer or sealed using our Tape-Kote Roof Seam Tape. (Safe-T-Plex forms a watertight adhesive bond to this tape.)  Apply Tape-Kote Seam Tape around all objects that protrude through the roof (air conditioners, vents, breather pipes, etc.).

STEEL ROOF APPLICATION
All rusty roof surfaces must be primed using Rustite Metal Primer at least 24  hours prior to applying Safe-T-Plex Elastomeric Roof Coating.
Do not apply Safe-T-Plex if rain, heavy dew, or frost appears imminent during the next 24 hours. Minimum temperature during application and curing must be 10ºC (50ºC).